Safety requirements for processing of medical wiring harness terminals

Date: 2021-03-30 Visited: 422

Medical wiring harness terminals are processed by a stamping die. The main process equipment for precision stamping parts processing is the stamping die, because the medical wiring harness terminals are completed by the relative movement of the upper and lower dies. If the operator's fingers continue to enter or stay in the mold closed area, it will bring serious threats to their personal safety.


Guide parts Guide posts and guide sleeves are the most widely used guide parts of medical wiring harness terminals. Guide pillar, guide sleeve clearance should be smaller than the blanking clearance because its role is to ensure that the punch and concave die in the stamping work with accurate clearance. The guide post should be arranged far away from the module and the pressing plate, so that the operator's arm does not have to cross the guide post to send material, otherwise it will seriously threaten their personal safety.


The terminal die support and clamping parts of medical wiring harness include upper and lower formwork, die handle, convex and concave die fixing plate, backing plate, limiter, etc. The base part of the die is the upper and lower formwork, and the other parts are respectively installed and fixed on it. The plane size of the template, especially the front and back direction should be adapted to the parts, too large or too small are not conducive to operation. In order to facilitate the production of some molds, it is necessary to set up a backing plate under the die frame. At this time, the plate is best connected with a screw between the template, and the thickness of the two plates should be absolutely equal. In order to avoid the template fracture, the spacing of the pad should not be too large, so as to be able to prevail.